Pulse/pkg/server
rcourtman 6427f28a08 Fix stale metrics store reference in reporting engine after monitor reload
The reporting engine held a direct pointer to the metrics store, which
becomes invalid after a monitor reload (settings change, node config
save, etc.) closes and recreates the store. Use a dynamic getter closure
that always resolves to the current monitor's active store.

Also adds diagnostic logging when report queries return zero metrics,
and integration tests covering the full metrics-to-report pipeline
including reload scenarios.

Fixes #1186
2026-02-04 12:34:40 +00:00
..
metrics_test.go test: Add comprehensive test coverage across packages 2026-01-19 19:26:18 +00:00
server.go Fix stale metrics store reference in reporting engine after monitor reload 2026-02-04 12:34:40 +00:00
server_helpers_test.go test: Add comprehensive test coverage across packages 2026-01-19 19:26:18 +00:00
server_test.go refactor(config): rename BackendHost/BackendPort to BindAddress 2026-02-01 23:26:32 +00:00