The PVE disks/list poll and the agent SMART report both observe a RAID controller's exported volume, but PVE surfaces its NAA identifier as a bare-hex serial while smartctl reports the same value as a naa.-prefixed WWN with no serial. The linked-disk join compared serial to serial and WWN to WWN verbatim, so the volume rendered twice (/dev/sda and sda) with independent metric histories. Hardware identity comparison now normalizes reporter framing (naa., eui., wwn-, 0x prefixes, case) and folds serial and WWN together before comparing. Values are never truncated: sibling volumes on one controller share their leading WWN bytes, and a truncated udev ID_WWN must stay unequal to a full identifier. Placeholder serials no longer count as an identity match. Refs #1720 |
||
|---|---|---|
| .. | ||
| identity.go | ||
| identity_test.go | ||
| status.go | ||
| status_clone_branchcov0720pm_test.go | ||
| status_test.go | ||