Commit graph

13 commits

Author SHA1 Message Date
rcourtman
5c54685f04 Add API token scopes and standalone host agent
Introduces granular permission scopes for API tokens (docker:report, docker:manage, host-agent:report, monitoring:read/write, settings:read/write) allowing tokens to be restricted to minimum required access. Legacy tokens default to full access until scopes are explicitly configured.

Adds standalone host agent for monitoring Linux, macOS, and Windows servers outside Proxmox/Docker estates. New Servers workspace in UI displays uptime, OS metadata, and capacity metrics from enrolled agents.

Includes comprehensive token management UI overhaul with scope presets, inline editing, and visual scope indicators.
2025-10-23 11:40:31 +00:00
rcourtman
aac3dacd63 Improve LXC guest metrics visibility (#596) 2025-10-22 22:24:33 +00:00
rcourtman
3a3e0e080c Add replication monitoring plumbing and UI
Refs #395
2025-10-22 16:10:15 +00:00
rcourtman
c9543e8a7e Add qemu guest agent version metadata 2025-10-22 15:24:07 +00:00
rcourtman
cdf80dbab5 Align backup node column with current host (#577) 2025-10-22 13:47:51 +00:00
rcourtman
be26f957c0 Add snapshot size alert thresholds (#585) 2025-10-22 13:30:40 +00:00
Pulse Automation Bot
cfdfe896be Adjust backup and snapshot alert handling 2025-10-18 20:11:01 +00:00
Richard Courtman
97b9c6739c feat: add min/max temperature tracking for nodes
Track minimum and maximum CPU temperatures since monitoring started.
This provides better insight into temperature trends and cooling
adequacy over time.

Changes:
- Backend: Add CPUMin, CPUMaxRecord, MinRecorded, MaxRecorded fields
  to Temperature model
- Backend: Implement min/max tracking logic in monitoring cycle that
  preserves values across polling cycles
- Backend: Initialize min/max on first reading, update on extremes
- Frontend: Update Temperature TypeScript interface with new fields
- Frontend: Display min/max range in NodeCard tooltip (e.g., "52°C
  (48-67°C since monitoring started)")
- Frontend: Rebuild dist assets

Temperature display now shows:
- Current temperature with color coding (green/yellow/red)
- Tooltip with full min-max range and context
- Min/max tracked in-memory (resets on Pulse restart)

Example tooltip: "CPU: 52°C (48-67°C since monitoring started)"

🤖 Generated with [Claude Code](https://claude.com/claude-code)

Co-Authored-By: Claude <noreply@anthropic.com>
2025-10-18 08:15:10 +00:00
rcourtman
91fecacfef feat: add docker agent command handling 2025-10-15 19:27:19 +00:00
rcourtman
881b7f9a54 Fix false ZFS log/cache warnings 2025-10-14 20:57:43 +00:00
rcourtman
5c79d2516d feat: streamline docker agent onboarding 2025-10-14 09:45:32 +00:00
rcourtman
dd9bd65a2e fix: Add hasCPU/hasNVMe flags to prevent false 'no CPU sensor' errors
Addresses #101

v4.23.0 introduced a regression where systems with only NVMe temperatures
(no CPU sensor) would display "No CPU sensor" in the UI. This was caused
by the Available flag being set to true when NVMe temps existed, even
without CPU data, triggering the error message in the frontend.

Backend changes:
- Add HasCPU and HasNVMe boolean fields to Temperature model
- Extend CPU sensor detection to support more chip types: zenpower,
  k8temp, acpitz, it87 (case-insensitive matching)
- HasCPU is set based on CPU chip detection (coretemp, k10temp, etc.),
  not value thresholds
- This prevents false negatives when sensors report 0°C during resets
- CPU temperature values now accepted even when 0 (checked with !IsNaN
  instead of > 0)
- extractTempInput returns NaN instead of 0 when no data found
- Available flag means "any temperature data exists" for backward compatibility
- Update mock generator to properly set the new flags
- Add unit tests for NVMe-only and 0°C scenarios to prevent regression
- Removed amd_energy from CPU chip list (power sensor, not temperature)

Frontend changes:
- Add hasCPU and hasNVMe optional fields to Temperature interface
- Update NodeSummaryTable to check hasCPU flag with fallback to available
  for backward compatibility with older API responses
- Update NodeCard temperature display logic with same fallback pattern
- Systems with only NVMe temps now show "-" instead of error message
- Fallback ensures UI works with both old and new API responses

Testing:
- All unit tests pass including NVMe-only and 0°C test cases
- Fix prevents false "no CPU sensor" errors when sensors temporarily report 0°C
- Fix eliminates false "no CPU sensor" errors for NVMe-only systems
2025-10-13 10:17:17 +00:00
rcourtman
f46ff1792b Fix settings security tab navigation 2025-10-11 23:29:47 +00:00