The output of the modulator or resampler is scaled and
converted from floating point to fixed point. The scaling
factor is the leftover dB in RF attention (relative to max
transmit power), which is handled prior to the integer
conversion. This should work across all daughterboards and
non-UHD installations.
Signed-off-by: Thomas Tsou <ttsou@vt.edu>
git-svn-id: http://wush.net/svn/range/software/public/openbts/trunk@2650 19bc5d8c-e614-43d4-8b26-e1612bc8e597
Previously this was referenced off the the ad9862
PGA with a range from 0 to -20 dB. Instead base
the attenuation factor on the maximum total RF
gain returned by the device.
Signed-off-by: Thomas Tsou <ttsou@vt.edu>
git-svn-id: http://wush.net/svn/range/software/public/openbts/trunk@2649 19bc5d8c-e614-43d4-8b26-e1612bc8e597
'loadTest' variable was never initialized sometimes causing
segmentation fault on transceiver startup.
Signed-off-by: Thomas Tsou <ttsou@vt.edu>
git-svn-id: http://wush.net/svn/range/software/public/openbts/trunk@2631 19bc5d8c-e614-43d4-8b26-e1612bc8e597