The output of the modulator or resampler is scaled and
converted from floating point to fixed point. The scaling
factor is the leftover dB in RF attention (relative to max
transmit power), which is handled prior to the integer
conversion. This should work across all daughterboards and
non-UHD installations.
Signed-off-by: Thomas Tsou <ttsou@vt.edu>
git-svn-id: http://wush.net/svn/range/software/public/openbts/trunk@2650 19bc5d8c-e614-43d4-8b26-e1612bc8e597
Similar to the non-52 Mhz case,
589dd9091ef594ef6ef5804fbf6bfa70f3f02858
This drastically reduces underruns on the E100.
Signed-off-by: Thomas Tsou <ttsou@vt.edu>
git-svn-id: http://wush.net/svn/range/software/public/openbts/trunk@2648 19bc5d8c-e614-43d4-8b26-e1612bc8e597
Push the ability to set thread priority out to the 52M
Transceiver interface, because that's where the thread
control exists.
Signed-off-by: Thomas Tsou <ttsou@vt.edu>
git-svn-id: http://wush.net/svn/range/software/public/openbts/trunk@2644 19bc5d8c-e614-43d4-8b26-e1612bc8e597