.TH INXI 1 "2020\-04\-22" inxi "inxi manual"
|
|
|
|
.SH NAME
|
|
inxi \- Command line system information script for console and IRC
|
|
|
|
.SH SYNOPSIS
|
|
\fBinxi\fR
|
|
|
|
\fBinxi\fR [\fB\-AbBCdDfFGhijJIlmMnNopPrRsSuUVwzZ\fR]
|
|
|
|
\fBinxi\fR [\fB\-c NUMBER\fR] [\fB\-t\fR
|
|
[\fBc\fR|\fBm\fR|\fBcm\fR|\fBmc\fR][\fBNUMBER\fR]]
|
|
[\fB\-v NUMBER\fR] [\fB\-W LOCATION\fR]
|
|
[\fB\-\-weather\-unit\fR {\fBm\fR|\fBi\fR|\fBmi\fR|\fBim\fR}] [\fB\-y WIDTH\fR]
|
|
|
|
\fBinxi\fR [\fB\-\-memory\-modules\fR] [\fB\-\-memory\-short\fR]
|
|
[\fB\-\-recommends\fR] [\fB\-\-slots\fR]
|
|
|
|
\fBinxi\fB [\fB\-x\fR|\fB\-xx\fR|\fB\-xxx\fR|\fB\-a\fR] \fB\-OPTION(s)\fR
|
|
|
|
All short form options have long form variants \- see below for these and more advanced options.
|
|
|
|
.SH DESCRIPTION
|
|
\fBinxi\fR is a command line system information script built for console
|
|
and IRC. It is also used a debugging tool for forum technical support
|
|
to quickly ascertain users' system configurations and hardware. inxi shows
|
|
system hardware, CPU, drivers, Xorg, Desktop, Kernel, gcc version(s), Processes,
|
|
RAM usage, and a wide variety of other useful information.
|
|
|
|
\fBinxi\fR output varies depending on whether it is being used on CLI or IRC,
|
|
with some default filters and color options applied only for IRC use.
|
|
Script colors can be turned off if desired with \fB\-c 0\fR, or changed
|
|
using the \fB\-c\fR color options listed in the STANDARD OPTIONS section below.
|
|
|
|
.SH PRIVACY AND SECURITY
|
|
In order to maintain basic privacy and security, inxi used on IRC automatically
|
|
filters out your network device MAC address, WAN and LAN IP, your \fB/home\fR
|
|
username directory in partitions, and a few other items.
|
|
|
|
Because inxi is often used on forums for support, you can also trigger this
|
|
filtering with the \fB\-z\fR option (\fB\-Fz\fR, for example). To override
|
|
the IRC filter, you can use the \fB\-Z\fR option. This can be useful in debugging
|
|
network connection issues online in a private chat, for example.
|
|
|
|
.SH USING OPTIONS
|
|
Options can be combined if they do not conflict. You can either group the letters
|
|
together or separate them.
|
|
|
|
Letters with numbers can have no gap or a gap at your discretion, except when
|
|
using \fB \-t\fR. Note that if you use an option that requires an additional
|
|
argument, that must be last in the short form group of options. Otherwise
|
|
you can use those separately as well.
|
|
|
|
For example:
|
|
\fBinxi \-AG\fR | \fBinxi \-A \-G\fR | \fBinxi \-b\fR | \fBinxi \-c10\fR
|
|
| \fBinxi \-FxxzJy80\fR
|
|
|
|
Note that all the short form options have long form equivalents, which are
|
|
listed below. However, usually the short form is used in examples in order to
|
|
keep things simple.
|
|
|
|
.SH STANDARD OPTIONS
|
|
|
|
.TP
|
|
.B \-A\fR,\fB \-\-audio\fR
|
|
Show Audio/sound card(s) information, including card driver.
|
|
|
|
.TP
|
|
.B \-b\fR,\fB \-\-basic\fR
|
|
Show basic output, short form. Same as: \fBinxi \-v 2\fR
|
|
|
|
.TP
|
|
.B \-B\fR,\fB \-\-battery\fR
|
|
Show system battery (\fBID\-x\fR) data, charge, condition, plus extra information
|
|
(if battery present). Uses \fB/sys\fR or, for BSDs without systctl battery data,
|
|
\fBdmidecode\fR. \fBdmidecode\fR does not have very much information, and none
|
|
about current battery state/charge/voltage. Supports multiple batteries when
|
|
using \fB/sys\fR data.
|
|
|
|
Note that for \fBcharge\fR, the output shows the current charge, as well as its
|
|
value as a percentage of the available capacity, which can be less than the original design
|
|
capacity. In the following example, the actual current available capacity of the battery
|
|
is \fB22.2 Wh\fR.
|
|
|
|
\fBcharge: 20.1 Wh 95.4%\fR
|
|
|
|
The \fBcondition\fR item shows the remaining available capacity / original design
|
|
capacity, and then this figure as a percentage of original capacity available in the battery.
|
|
|
|
\fBcondition: 22.2/36.4 Wh (61%)\fR
|
|
|
|
With \fB\-x\fR shows attached \fBDevice\-x\fR information (mouse, keyboard, etc.)
|
|
if they are battery powered.
|
|
|
|
.TP
|
|
.B \-c\fR,\fB \-\-color\fR \fR[\fB0\fR\-\fB42\fR]
|
|
Set color scheme. If no scheme number is supplied, 0 is assumed.
|
|
|
|
.TP
|
|
.B \-c \fR[\fB94\fR\-\fB99\fR]
|
|
|
|
These color selectors run a color selector option prior to inxi starting which lets
|
|
you set the config file value for the selection.
|
|
|
|
NOTE: All configuration file set color values are removed when output is
|
|
piped or redirected. You must use the explicit runtime \fB\-c <color number>\fR option
|
|
if you want color codes to be present in the piped/redirected output.
|
|
|
|
Color selectors for each type display (NOTE: IRC and global only show safe color set):
|
|
|
|
.TP
|
|
.B \-c 94\fR
|
|
\- Console, out of X.
|
|
|
|
.TP
|
|
.B \-c 95\fR
|
|
\- Terminal, running in X \- like xTerm.
|
|
|
|
.TP
|
|
.B \-c 96\fR
|
|
\- GUI IRC, running in X \- like XChat, Quassel,
|
|
Konversation etc.
|
|
|
|
.TP
|
|
.B \-c 97\fR
|
|
\- Console IRC running in X \- like irssi in xTerm.
|
|
|
|
.TP
|
|
.B \-c 98\fR
|
|
\- Console IRC not in X.
|
|
|
|
.TP
|
|
.B \-c 99\fR
|
|
\- Global \- Overrides/removes all settings.
|
|
|
|
Setting a specific color type removes the global color selection.
|
|
|
|
.TP
|
|
.B \-C\fR,\fB \-\-cpu\fR
|
|
Show full CPU output, including per CPU clock speed and CPU max speed (if available).
|
|
If max speed data present, shows \fB(max)\fR in short output formats (\fBinxi\fR,
|
|
\fBinxi \-b\fR) if actual CPU speed matches max CPU speed. If max CPU speed does
|
|
not match actual CPU speed, shows both actual and max speed information.
|
|
See \fB\-x\fR for more options.
|
|
|
|
For certain CPUs (some ARM, and AMD Zen family) shows CPU die count.
|
|
|
|
The details for each CPU include a technical description e.g. \fBtype: MT MCP\fR
|
|
|
|
* \fBMT\fR \- Multi/Hyper Threaded CPU, more than 1 thread per core (previously \fBHT\fR).
|
|
|
|
* \fBMCM\fR \- Multi Chip Model (more than 1 die per CPU).
|
|
|
|
* \fBMCP\fR \- Multi Core Processor (more than 1 core per CPU).
|
|
|
|
* \fBSMP\fR \- Symmetric Multi Processing (more than 1 physical CPU).
|
|
|
|
* \fBUP\fR \- Uni (single core) Processor.
|
|
|
|
.TP
|
|
.B \-d\fR,\fB \-\-disk\-full\fR,\fB\-\-optical\fR
|
|
Show optical drive data as well as \fB\-D\fR hard drive data. With \fB\-x\fR, adds a
|
|
feature line to the output. Also shows floppy disks if present. Note that there is
|
|
no current way to get any information about the floppy device that we are aware of,
|
|
so it will simply show the floppy ID without any extra data. \fB\-xx\fR adds a
|
|
few more features.
|
|
|
|
.TP
|
|
.B \-D\fR,\fB \-\-disk\fR
|
|
Show Hard Disk info. Shows total disk space and used percentage. The disk used
|
|
percentage includes space used by swap partition(s), since those are not usable
|
|
for data storage. Note that with RAID disks, the percentage will be wrong since
|
|
the total is computed from the disk sizes, but used is computed from mounted
|
|
partition used percentages. This small defect may get corrected in the future.
|
|
Also, unmounted partitions are not counted in disk use percentages since inxi
|
|
has no access to the used amount.
|
|
|
|
Also shows per disk information: Disk ID, type (if present), vendor (if detected),
|
|
model, and size. See \fBExtra Data Options\fR (\fB\-x\fR options) and
|
|
\fBAdmin Extra Data Options\fR (\fB\-\-admin\fR options) for many more features.
|
|
|
|
.TP
|
|
.B \-\-filter\fR,\fB \-\-filter\-override\fR \- See \fB\-z\fR, \fB\-Z\fR.
|
|
|
|
.TP
|
|
.B \-\-filter\-label\fR
|
|
Filter partition label names from \fB\-j\fR, \fB\-o\fR, \fB\-p\fR,
|
|
\fB\-P\fR, and \fB\-Sa\fR (root=LABEL=...). Generally only useful in
|
|
very specialized cases.
|
|
|
|
.TP
|
|
.B \-\-filter\-uuid\fR
|
|
Filter partition UUIDs from \fB\-j\fR, \fB\-o\fR, \fB\-p\fR,
|
|
\fB\-P\fR, and \fB\-Sa\fR (root=UUID=...). Generally only useful in
|
|
very specialized cases.
|
|
|
|
.TP
|
|
.B \-f\fR,\fB \-\-flags\fR
|
|
Show all CPU flags used, not just the short list. Not shown with \fB\-F\fR in order
|
|
to avoid spamming. ARM CPUs: show \fBfeatures\fR items.
|
|
|
|
.TP
|
|
.B \-F\fR,\fB \-\-full\fR
|
|
Show Full output for inxi. Includes all Upper Case line letters except \fB\-W\fR,
|
|
plus \fB\-\-swap\fR, \fB\-s\fR and \fB\-n\fR. Does not show extra verbose options such as
|
|
\fB\-d \-f \-i \-l \-m \-o \-p \-r \-t \-u \-x\fR unless you use those arguments in
|
|
the command, e.g.: \fBinxi \-Frmxx\fR
|
|
|
|
.TP
|
|
.B \-G\fR,\fB \-\-graphics\fR
|
|
Show Graphic card(s) information, including details of card and card driver,
|
|
display protocol (if available), display server (and/or Wayland compositor),
|
|
vendor and version number, e.g.:
|
|
|
|
\fBDisplay: x11 server: Xorg 1.15.1\fR
|
|
|
|
If protocol is not detected, shows:
|
|
|
|
\fBDisplay: server: Xorg 1.15.1\fR
|
|
|
|
Also shows screen resolution(s) (per monitor/X screen), OpenGL renderer,
|
|
OpenGL core profile version/OpenGL version.
|
|
|
|
Compositor information will show if detected using \fB\-xx\fR option
|
|
or always if detected and Wayland.
|
|
|
|
.TP
|
|
.B \-h\fR,\fB \-\-help\fR
|
|
The help menu. Features dynamic sizing to fit into terminal window. Set script
|
|
global \fBCOLS_MAX_CONSOLE\fR if you want a different default value, or
|
|
use \fB\-y <width>\fR to temporarily override the defaults or actual window width.
|
|
|
|
.TP
|
|
.B \-i\fR,\fB \-\-ip\fR
|
|
Show WAN IP address and local interfaces (latter requires \fBifconfig\fR or
|
|
\fBip\fR network tool), as well as network output from \fB\-n\fR.
|
|
Not shown with \fB\-F\fR for user security reasons. You shouldn't paste your
|
|
local/WAN IP. Shows both IPv4 and IPv6 link IP addresses.
|
|
|
|
.TP
|
|
.B \-I\fR,\fB \-\-info\fR
|
|
Show Information: processes, uptime, memory, IRC client (or shell type if run in
|
|
shell, not IRC), inxi version. See \fB\-x\fR and \fB\-xx\fR for extra information
|
|
(init type/version, runlevel).
|
|
|
|
Note: if \fB\-m\fR is used or triggered, the memory item will show in the main
|
|
Memory: report of \fB\-m\fR, not in \fB\Info:\fR.
|
|
|
|
Rasberry Pi only: uses \fBvcgencmd get_mem gpu\fR to get gpu RAM amount,
|
|
if user is in video group and \fBvcgencmd\fR is installed. Uses
|
|
this result to increase the \fBMemory:\fR amount and \fBused:\fR amounts.
|
|
|
|
.TP
|
|
.B \-j\fR, \fB\-\-swap\fR
|
|
Shows all active swap types (partition, file, zram). When this option is used,
|
|
swap partition(s) will not show on the \fB\-P\fR line to avoid redundancy.
|
|
|
|
.TP
|
|
.B \-J\fR,\fB \-\-usb\fR
|
|
Show USB data for attached Hubs and Devices. Hubs also show number of ports.
|
|
Be aware that a port is not always external, some may be internal, and either
|
|
used or unused (for example, a motherboard USB header connector that is not used).
|
|
|
|
Hubs and Devices are listed in order of BusID.
|
|
|
|
BusID is generally in this format: BusID\-port[.port][.port]:DeviceID
|
|
|
|
Device ID is a number created by the kernel, and has no necessary ordering
|
|
or sequence connection, but can be used to match this output to lsusb
|
|
values, which generally shows BusID / DeviceID (except for tree view, which
|
|
shows ports).
|
|
|
|
Examples: \fBDevice\-3: 4\-3.2.1:2\fR or \fBHub: 4\-0:1\fR
|
|
|
|
The \fBrev: 2.0\fR item refers to the USB revision number, like \fB1.0\fR or
|
|
\fB3.1\fR.
|
|
|
|
.TP
|
|
.B \-l\fR,\fB \-\-label\fR
|
|
Show partition labels. Default: main partitions \fB\-P\fR. For full \fB\-p\fR output,
|
|
use: \fB\-pl\fR.
|
|
|
|
.TP
|
|
.B \-m\fR,\fB \-\-memory\fR
|
|
Memory (RAM) data. Does not display with \fB\-b\fR or \fB\-F\fR unless you use \fB\-m\fR
|
|
explicitly. Ordered by system board physical system memory array(s) (\fBArray\-[number]\fR),
|
|
and individual memory devices (\fBDevice\-[number]\fR). Physical memory
|
|
array data shows array capacity, number of devices supported, and Error Correction
|
|
information. Devices shows locator data (highly variable in syntax), size, speed,
|
|
type (eg: \fBtype: DDR3\fR).
|
|
|
|
Note: \fB\-m\fR uses \fBdmidecode\fR, which must be run as root (or start
|
|
\fBinxi\fR with \fBsudo\fR), unless you figure out how to set up sudo to permit
|
|
dmidecode to read \fB/dev/mem\fR as user. \fBspeed\fR and \fBbus width\fR will not
|
|
show if \fBNo Module Installed\fR is found in \fBsize\fR.
|
|
|
|
Note: If \fB\-m\fR is triggered RAM total/used report will appear in this section,
|
|
not in \fB\-I\fR or \fB\-tm\fR items.
|
|
|
|
Because \fBdmidecode\fR data is extremely unreliable, inxi will try to make best guesses.
|
|
If you see \fB(check)\fR after the capacity number, you should check it with the
|
|
specifications. \fB(est)\fR is slightly more reliable, but you should still check
|
|
the real specifications before buying RAM. Unfortunately there is nothing \fBinxi\fR
|
|
can do to get truly reliable data about the system RAM; maybe one day the kernel devs
|
|
will put this data into \fB/sys\fR, and make it real data, taken from the actual system,
|
|
not dmi data. For most people, the data will be right, but a significant percentage of
|
|
users will have either a wrong max module size, if present, or max capacity.
|
|
|
|
See \fB\-\-memory\-modules\fR and \fB\-\-memory\-short\fR if you want a shorter report.
|
|
|
|
.TP
|
|
.B \-\-memory\-modules\fR
|
|
Memory (RAM) data. Show only RAM arrays and modules in Memory report.
|
|
Skip empty slots. See \fB\-m\fR.
|
|
|
|
.TP
|
|
.B \-\-memory\-short\fR
|
|
Memory (RAM) data. Show a one line RAM report in Memory. See \fB\-m\fR.
|
|
|
|
Sample: \fBReport: arrays: 1 slots: 4 modules: 2 type: DDR4\fR
|
|
|
|
.TP
|
|
.B \-M\fR,\fB \-\-machine\fR
|
|
Show machine data. Device, Motherboard, BIOS, and if present, System Builder (Like Lenovo).
|
|
Older systems/kernels without the required \fB/sys\fR data can use \fBdmidecode\fR instead, run
|
|
as root. If using \fBdmidecode\fR, may also show BIOS/UEFI revision as well as version.
|
|
\fB\-\-dmidecode\fR forces use of \fBdmidecode\fR data instead of \fB/sys\fR.
|
|
Will also attempt to show if the system was booted by BIOS, UEFI, or UEFI [Legacy], the
|
|
latter being legacy BIOS boot mode in a system board using UEFI.
|
|
|
|
Device information requires either \fB/sys\fR or \fBdmidecode\fR. Note that 'other\-vm?'
|
|
is a type that means it's usually a VM, but inxi failed to detect which type, or
|
|
positively confirm which VM it is. Primary VM identification is via systemd\-detect\-virt
|
|
but fallback tests that should also support some BSDs are used. Less commonly
|
|
used or harder to detect VMs may not be correctly detected. If you get an incorrect output,
|
|
post an issue and we'll get it fixed if possible.
|
|
|
|
Due to unreliable vendor data, device type will show: desktop, laptop, notebook, server,
|
|
blade, plus some obscure stuff that inxi is unlikely to ever run on.
|
|
|
|
.TP
|
|
.B \-n\fR,\fB \-\-network\-advanced\fR
|
|
Show Advanced Network card information in addition to that produced by \fB\-N\fR.
|
|
Shows interface, speed, MAC ID, state, etc.
|
|
|
|
.TP
|
|
.B \-N\fR,\fB \-\-network\fR
|
|
Show Network card(s) information, including card driver. With \fB\-x\fR, shows PCI BusID,
|
|
Port number.
|
|
|
|
.TP
|
|
.B \-o\fR,\fB \-\-unmounted\fR
|
|
Show unmounted partition information (includes UUID and LABEL if available).
|
|
Shows file system type if you have \fBlsblk\fR installed (Linux only). For BSD/GNU Linux:
|
|
shows file system type if \fBfile\fR is installed, and if you are root or
|
|
if you have added to \fB/etc/sudoers\fR (sudo v. 1.7 or newer):
|
|
|
|
.B <username> ALL = NOPASSWD: /usr/bin/file (sample)
|
|
|
|
Does not show components (partitions that create the md\-raid array) of md\-raid arrays.
|
|
|
|
.TP
|
|
.B \-p\fR,\fB \-\-partitions\-full\fR
|
|
Show full Partition information (\fB\-P\fR plus all other detected mounted partitions).
|
|
|
|
.TP
|
|
.B \-P\fR,\fB \-\-partitions\fR
|
|
Show basic Partition information.
|
|
Shows, if detected: \fB/ /boot /home /opt /tmp /usr /usr/home /var /var/tmp /var/log\fR.
|
|
If \fB\-\-swap\fR is not used, shows active swap partitions (never shows file or
|
|
zram type swap).
|
|
Use \fB\-p\fR to see all mounted partitions.
|
|
|
|
.TP
|
|
.B \-\-processes\fR \- See \fB\-t\fR
|
|
|
|
.TP
|
|
.B \-r\fR,\fB \-\-repos\fR
|
|
Show distro repository data. Currently supported repo types:
|
|
|
|
\fBAPK\fR (Alpine Linux + derived versions)
|
|
|
|
\fBAPT\fR (Debian, Ubuntu + derived versions, as well as RPM based
|
|
APT distros like PCLinuxOS or Alt\-Linux)
|
|
|
|
\fBCARDS\fR (NuTyX + derived versions)
|
|
|
|
\fBEOPKG\fR (Solus)
|
|
|
|
\fBPACMAN\fR (Arch Linux, KaOS + derived versions)
|
|
|
|
\fBPACMAN\-G2\fR (Frugalware + derived versions)
|
|
|
|
\fBPISI\fR (Pardus + derived versions)
|
|
|
|
\fBPORTAGE\fR (Gentoo, Sabayon + derived versions)
|
|
|
|
\fBPORTS\fR (OpenBSD, FreeBSD, NetBSD + derived OS types)
|
|
|
|
\fBSLACKPKG\fR (Slackware + derived versions)
|
|
|
|
\fBTCE\fR (TinyCore)
|
|
|
|
\fBURPMQ\fR (Mandriva, Mageia + derived versions)
|
|
|
|
\fBXBPS\fR (Void)
|
|
|
|
\fBYUM/ZYPP\fR (Fedora, Red Hat, Suse + derived versions)
|
|
|
|
More will be added as distro data is collected. If yours is missing please
|
|
show us how to get this information and we'll try to add it.
|
|
|
|
.TP
|
|
.B \-R\fR,\fB \-\-raid\fR
|
|
Show RAID data. Shows RAID devices, states, levels and components, and
|
|
extra data with \fB\-x\fR / \fB\-xx\fR.
|
|
|
|
md\-raid: If device is resyncing, also shows resync progress line.
|
|
|
|
Note: Only md\-raid and ZFS are currently supported. Other software RAID types could
|
|
be added, but only if users supply all data required, and if the software
|
|
RAID actually can be made to give the required output.
|
|
|
|
If hardware RAID is detected, shows basic information. Due to complexity
|
|
of adding hardware RAID device disk / RAID reports, those will only be added
|
|
if there is demand, and reasonable reporting tools.
|
|
|
|
.TP
|
|
.B \-\-recommends\fR
|
|
Checks inxi application dependencies and recommends, as well as directories,
|
|
then shows what package(s) you need to install to add support for each feature.
|
|
|
|
.TP
|
|
.B \-s\fR,\fB \-\-sensors\fR
|
|
Show output from sensors if sensors installed/configured: Motherboard/CPU/GPU
|
|
temperatures; detected fan speeds. GPU temperature when available. Nvidia shows
|
|
screen number for multiple screens. IPMI sensors are also used (root required)
|
|
if present.
|
|
.
|
|
.TP
|
|
.B \-\-slots\fR
|
|
Show PCI slots with type, speed, and status information.
|
|
|
|
.TP
|
|
.B \-\-swap\fR \- See \fB\-j\fR
|
|
|
|
.TP
|
|
.B \-S\fR,\fB \-\-system\fR
|
|
Show System information: host name, kernel, desktop environment (if in X),
|
|
distro. With \fB\-xx\fR show dm \- or startx \- (only shows if present and
|
|
running if out of X), and if in X, with \fB\-xxx\fR show more desktop info,
|
|
e.g. taskbar or panel.
|
|
|
|
.TP
|
|
.B \-t\fR,\fB \-\-processes\fR
|
|
[\fBc\fR|\fBm\fR|\fBcm\fR|\fBmc NUMBER\fR] Show processes. If no arguments, defaults to \fBcm\fR.
|
|
If followed by a number, shows that number of processes for each type
|
|
(default: \fB5\fR; if in IRC, max: \fB5\fR)
|
|
|
|
Make sure that there is no space between letters and numbers (e.g. write as \fB\-t cm10\fR).
|
|
|
|
.TP
|
|
.B \-t c\fR
|
|
\- CPU only. With \fB\-x\fR, also shows memory for that process on same line.
|
|
|
|
.TP
|
|
.B \-t m\fR
|
|
\- memory only. With \fB\-x\fR, also shows CPU for that process on same line.
|
|
If the \-I line is not triggered, will also show the system RAM used/total
|
|
information.
|
|
|
|
.TP
|
|
.B \-t cm\fR
|
|
\- CPU+memory. With \fB\-x\fR, shows also CPU or memory for that process on
|
|
same line.
|
|
|
|
.TP
|
|
.B \-u\fR,\fB \-\-uuid\fR
|
|
Show partition UUIDs. Default: main partitions \fB\-P\fR. For full \fB\-p\fR
|
|
output, use: \fB\-pu\fR.
|
|
|
|
.TP
|
|
.B \-U\fR,\fB \-\-update\fR
|
|
Note \- Maintainer may have disabled this function.
|
|
|
|
If inxi \fB\-h\fR has no listing for \fB\-U\fR then it's disabled.
|
|
|
|
Auto\-update script. Note: if you installed as root, you must be root to
|
|
update, otherwise user is fine. Also installs / updates this man page to:
|
|
\fB/usr/local/share/man/man1\fR (if \fB/usr/local/share/man/\fR exists
|
|
AND there is no inxi man page in \fB/usr/share/man/man1\fR, otherwise it
|
|
goes to \fB/usr/share/man/man1\fR). This requires that you be root to write
|
|
to that directory. See \fB\-\-man\fR or \fB\-\-no\-man\fR to force or disable
|
|
man install.
|
|
|
|
.TP
|
|
.B \-\-usb\fR \- See \fB\-J\fR
|
|
|
|
.TP
|
|
.B \-V\fR, \fB\-\-version\fR
|
|
inxi version information. Prints information then exits.
|
|
|
|
.TP
|
|
.B \-v\fR,\fB \-\-verbosity\fR
|
|
Script verbosity levels. If no verbosity level number is given, 0 is assumed.
|
|
Should not be used with \fB\-b\fR or \fB\-F\fR.
|
|
|
|
Supported levels: \fB0\-8\fR Examples :\fB inxi \-v 4 \fR or \fB inxi \-v4\fR
|
|
|
|
.TP
|
|
.B \-v 0
|
|
\- Short output, same as: \fBinxi\fR
|
|
|
|
.TP
|
|
.B \-v 1
|
|
\- Basic verbose, \fB\-S\fR + basic CPU (cores, type, clock speed, and min/max
|
|
speeds, if available) + \fB\-G\fR + basic Disk + \fB\-I\fR.
|
|
|
|
.TP
|
|
.B \-v 2
|
|
\- Adds networking card (\fB\-N\fR), Machine (\fB\-M\fR) data, Battery (\fB\-B\fR)
|
|
(if available). Same as: \fBinxi \-b\fR
|
|
|
|
.TP
|
|
.B \-v 3
|
|
\- Adds advanced CPU (\fB\-C\fR) and network (\fB\-n\fR) data; triggers \fB\-x\fR
|
|
advanced data option.
|
|
|
|
.TP
|
|
.B \-v 4
|
|
\- Adds partition size/used data (\fB\-P\fR) for (if present):
|
|
\fB/ /home /var/ /boot\fR. Shows full disk data (\fB\-D\fR)
|
|
|
|
.TP
|
|
.B \-v 5
|
|
\- Adds audio card (\fB\-A\fR), memory/RAM (\fB\-m\fR), sensors (\fB\-s\fR),
|
|
partition label (\fB\-l\fR), UUID (\fB\-u\fR), full swap data (\fB\-j\fR),
|
|
and short form of optical drives.
|
|
|
|
.TP
|
|
.B \-v 6
|
|
\- Adds full mounted partition data (\fB\-p\fR),
|
|
unmounted partition data (\fB\-o\fR), optical drive data (\fB\-d\fR),
|
|
USB (\fB\-J\fR); triggers \fB\-xx\fR extra data option.
|
|
|
|
.TP
|
|
.B \-v 7
|
|
\- Adds network IP data (\fB\-i\fR); triggers \fB\-xxx\fR
|
|
|
|
.TP
|
|
.B \-v 8
|
|
\- All system data available. Adds Repos (\fB\-r\fR), PCI slots (\fB\-\-slots\fR),
|
|
processes (\fB\-tcm\fR), admin (\fB\-\-admin\fR). Useful for testing output and to
|
|
see what data you can get from your system.
|
|
|
|
.TP
|
|
.B \-w\fR,\fB \-\-weather\fR
|
|
Adds weather line. To get weather for an alternate location, use
|
|
\fB\-W [location]\fR. See also \fB\-x\fR, \fB\-xx\fR, \fB\-xxx\fR options.
|
|
Please note that your distribution's maintainer may chose to disable this feature.
|
|
|
|
DO NOT USE THIS FEATURE FOR AUTOMATED WEATHER UPDATES! You will be blocked
|
|
from any further access. This feature is not meant for widget type
|
|
weather monitoring, or Conky type use. It is meant to get weather when you need to
|
|
see it, for example, on a remote server.
|
|
|
|
.TP
|
|
.B \-W\fR, \fB\-\-weather\-location <location_string>\fR
|
|
Get weather/time for an alternate location. Accepts postal/zip code[, country],
|
|
city,state pair, or latitude,longitude. Note: city/country/state names must not
|
|
contain spaces. Replace spaces with '\fB+\fR' sign. Don't place spaces around
|
|
any commas. Postal code is not reliable except for North America and maybe the UK.
|
|
Try postal codes with and without country code added. Note that City,State applies
|
|
only to USA, otherwise it's City,Country. If country name (english) does not work,
|
|
try 2 character country code (e.g. Spain: es; Great Britain: gb).
|
|
|
|
See \fIhttps://en.wikipedia.org/wiki/ISO_3166\-1_alpha\-2\fR for current 2 letter
|
|
country codes.
|
|
|
|
Use only ASCII letters in city/state/country names.
|
|
|
|
Examples: \fB\-W 95623,us\fR OR \fB\-W Boston,MA\fR OR
|
|
\fB\-W 45.5234,\-122.6762\fR OR \fB\-W new+york,ny\fR OR \fB\-W bodo,norway\fR.
|
|
|
|
DO NOT USE THIS FEATURE FOR AUTOMATED WEATHER UPDATES! Use of automated queries,
|
|
will result in your access being blocked. If you try to work around the ban, you
|
|
will be permanently banned from this service.
|
|
|
|
.TP
|
|
.B \-\-weather\-source\fR, \fB\-\-ws <unit>\fR
|
|
[\fB1\-9\fR] Switches weather data source. Possible values are \fB1\-9\fR. \fB1\-4\fR
|
|
will generally be active, and \fB5\-9\fR may or may not be active, so check.
|
|
\fB1\fR may not support city / country names with spaces (even if you use the \fB+\fR
|
|
sign instead of space). \fB2\fR offers pretty good data, but may not have all small
|
|
city names for \fB\-W\fR.
|
|
|
|
Please note that the data sources are not static per value, and can change any time,
|
|
or be removed, so always test to verify which source is being used for each value
|
|
if that is important to you. Data sources may be added or removed on occasions, so
|
|
try each one and see which you prefer. If you get unsupported source message, it means
|
|
that number has not been implemented.
|
|
|
|
.TP
|
|
.B \-\-weather\-unit <unit>\fR
|
|
[\fBm\fR|\fBi\fR|\fBmi\fR|\fBim\fR] Sets weather units to metric (\fBm\fR), imperial (\fBi\fR),
|
|
metric (imperial) (\fBmi\fR, default), imperial (metric) (\fBim\fR). If metric or imperial
|
|
not found,sets to default value, or \fBN/A\fR.
|
|
|
|
.TP
|
|
.B \-y\fR,\fB \-\-width <integer>\fR
|
|
This is an absolute width override which sets the output line width max.
|
|
Overrides \fBCOLS_MAX_IRC\fR / \fBCOLS_MAX_CONSOLE\fR globals, or the
|
|
actual widths of the terminal. \fB80\fR is the minimum width supported.
|
|
\fB\-1\fR removes width limits. Example: \fBinxi \-Fxx\ \-y 130\fR
|
|
|
|
.TP
|
|
.B \-z\fR,\fB \-\-filter\fR
|
|
Adds security filters for IP addresses, serial numbers, MAC,
|
|
location (\fB\-w\fR), and user home directory name. Removes Host:.
|
|
On by default for IRC clients.
|
|
|
|
.TP
|
|
.B \-Z\fR,\fB \-\-filter\-override\fR
|
|
Absolute override for output filters. Useful for debugging networking
|
|
issues in IRC for example.
|
|
|
|
.SH EXTRA DATA OPTIONS
|
|
These options can be triggered by one or more \fB\-x\fR.
|
|
Alternatively, the \fB\-v\fR options trigger them in the following
|
|
way: \fB\-v 3\fR adds \fB\-x\fR;
|
|
\fB\-v 6\fR adds \fB\-xx\fR; \fB\-v 7\fR adds \fB\-xxx\fR
|
|
|
|
These extra data triggers can be useful for getting more in\-depth
|
|
data on various options. They can be added to any long form option list,
|
|
e.g.: \fB\-bxx\fR or \fB\-Sxxx\fR
|
|
|
|
There are 3 extra data levels:
|
|
|
|
\fB\-x\fR, \fB\-xx\fR, \fB\-xxx\fR
|
|
|
|
OR
|
|
|
|
\fB\-\-extra 1\fR, \fB\-\-extra 2\fR, \fB\-\-extra 3\fR
|
|
|
|
The following details show which lines / items display extra information for each
|
|
extra data level.
|
|
|
|
.TP
|
|
.B \-x \-A\fR
|
|
\- Adds (if available and/or relevant) \fBvendor:\fR item, which shows
|
|
specific vendor [product] information.
|
|
|
|
\- Adds version/port(s)/driver version (if available) for each Audio
|
|
device.
|
|
|
|
\- Adds PCI Bus ID/USB ID number of each Audio device.
|
|
|
|
.TP
|
|
.B \-x \-B\fR
|
|
\- Adds vendor/model, battery status (if battery present).
|
|
|
|
\- Adds attached battery powered peripherals (\fBDevice\-[number]:\fR) if
|
|
detected (keyboard, mouse, etc.).
|
|
|
|
.TP
|
|
.B \-x \-C\fR
|
|
\- Adds bogomips on CPU (if available)
|
|
|
|
\- Adds CPU Flags (short list). Use \fB\-f\fR to see full flag/feature list.
|
|
|
|
\- Adds CPU microarchitecture + revision (e.g. Sandy Bridge, K8, ARMv8, P6,
|
|
etc.). Only shows data if detected. Newer microarchitectures will have
|
|
to be added as they appear, and require the CPU family ID and model ID.
|
|
|
|
Examples: \fBarch: Sandy Bridge rev: 2\fR, \fBarch: K8 rev.F+ rev: 2\fR
|
|
|
|
.TP
|
|
.B \-x \-d\fR
|
|
\- Adds more items to \fBFeatures\fR line of optical drive;
|
|
dds rev version to optical drive.
|
|
|
|
.TP
|
|
.B \-x \-D\fR
|
|
\- Adds HDD temperature with disk data if you have hddtemp installed, if you are root
|
|
or if you have added to \fB/etc/sudoers\fR (sudo v. 1.7 or newer):
|
|
|
|
.B <username> ALL = NOPASSWD: /usr/sbin/hddtemp (sample)
|
|
|
|
.TP
|
|
.B \-x \-G\fR
|
|
\- Adds (if available and/or relevant) \fBvendor:\fR item, which shows
|
|
specific vendor [product] information.
|
|
|
|
\- Adds direct rendering status.
|
|
|
|
\- Adds (for single GPU, nvidia driver) screen number that GPU is running on.
|
|
|
|
\- Adds PCI Bus ID/USB ID number of each Graphics card.
|
|
|
|
.TP
|
|
.B \-x \-i\fR
|
|
\- Adds IP v6 additional scope data, like Global, Site, Temporary for
|
|
each interface.
|
|
|
|
Note that there is no way we are aware of to filter out the deprecated
|
|
IP v6 scope site/global temporary addresses from the output of
|
|
\fBifconfig\fR. The \fBip\fR tool shows that clearly.
|
|
|
|
\fBip\-v6\-temporary\fR \- (\fBip\fR tool only), scope global temporary.
|
|
Scope global temporary deprecated is not shown
|
|
|
|
\fBip\-v6\-global\fR \- scope global (\fBifconfig\fR will show this for
|
|
all types, global, global temporary, and global temporary deprecated,
|
|
\fBip\fR shows it only for global)
|
|
|
|
\fBip\-v6\-link\fR \- scope link (\fBip\fR/\fBifconfig\fR) \- default
|
|
for \fB\-i\fR.
|
|
|
|
\fBip\-v6\-site\fR \- scope site (\fBip\fR/\fBifconfig\fR). This has been
|
|
deprecated in IPv6, but still exists. \fBifconfig\fR may show multiple site
|
|
values, as with global temporary, and global temporary deprecated.
|
|
|
|
\fBip\-v6\-unknown\fR \- unknown scope
|
|
|
|
.TP
|
|
.B \-x \-I\fR
|
|
\- Adds current init system (and init rc in some cases, like OpenRC).
|
|
With \fB\-xx\fR, shows init/rc version number, if available.
|
|
|
|
\- Adds default system gcc. With \fB\-xx\fR, also show other installed gcc
|
|
versions.
|
|
|
|
\- Adds current runlevel (not available with all init systems).
|
|
|
|
\- If in shell (i.e. not in IRC client), adds shell version number, if available.
|
|
|
|
.TP
|
|
.B \-x \-J\fR (\fB\-\-usb\fR)
|
|
\- For Devices, adds driver(s).
|
|
|
|
.TP
|
|
.B \-x \-m\fR, \fB\-\-memory\-modules\fR
|
|
\- If present, adds maximum memory module/device size in the Array line.
|
|
Only some systems will have this data available. Shows estimate if it can
|
|
generate one.
|
|
|
|
\- Adds device type in the Device line.
|
|
|
|
.TP
|
|
.B \-x \-N\fR
|
|
\- Adds (if available and/or relevant) \fBvendor:\fR item, which shows
|
|
specific vendor [product] information.
|
|
|
|
\- Adds version/port(s)/driver version (if available) for each Network card;
|
|
|
|
\- Adds PCI Bus ID/USB ID number of each Network card.
|
|
|
|
.TP
|
|
.B \-x \-R\fR
|
|
\- md\-raid: Adds second RAID Info line with extra data: blocks, chunk size,
|
|
bitmap (if present). Resync line, shows blocks synced/total blocks.
|
|
|
|
\- Hardware RAID: Adds driver version, bus ID.
|
|
|
|
.TP
|
|
.B \-x \-s\fR
|
|
\- Adds basic voltages: 12v, 5v, 3.3v, vbat (\fBipmi\fR, \fBlm-sensors\fR if present).
|
|
|
|
.TP
|
|
.B \-x \-S\fR
|
|
\- Adds Kernel gcc version.
|
|
|
|
\- Adds to \fBDistro:\fR \fBbase:\fR if detected. System base will only be seen on
|
|
a subset of distributions. The distro must be both derived from a parent distro (e.g. Mint from
|
|
Ubuntu), and explicitly added to the supported distributions for this feature. Due to
|
|
the complexity of distribution identification, these will only be added as relatively solid
|
|
methods are found for each distribution system base detection.
|
|
|
|
.TP
|
|
.B \-x \-t\fR (\fB\-\-processes\fR)
|
|
\- Adds memory use output to CPU (\fB\-xt c\fR), and CPU use to memory
|
|
(\fB\-xt m\fR).
|
|
|
|
.TP
|
|
.B \-x \-w\fR,\fB \-W\fR
|
|
\- Adds humidity and barometric pressure.
|
|
|
|
\- Adds wind speed and direction.
|
|
|
|
.TP
|
|
.B \-xx \-A\fR
|
|
\- Adds vendor:product ID for each Audio device.
|
|
|
|
.TP
|
|
.B \-xx \-B\fR
|
|
\- Adds serial number, voltage (if available). Note that \fBvolts\fR shows the
|
|
data (if available) as the voltage now / minimum design voltage.
|
|
|
|
.TP
|
|
.B \-xx \-C\fR
|
|
\- Adds \fBL1 cache:\fR and \fBL3 cache:\fR if either are available. Requires
|
|
dmidecode and sudo/root.
|
|
|
|
.TP
|
|
.B \-xx \-D\fR
|
|
\- Adds disk serial number.
|
|
|
|
\- Adds disk speed (if available). This is the theoretical top speed of the
|
|
device as reported. This speed may be restricted by system board limits, eg.
|
|
a SATA 3 drive on a SATA 2 board may report SATA 2 speeds, but this is not
|
|
completely consistent, sometimes a SATA 3 device on a SATA 2 board reports
|
|
its design speed.
|
|
|
|
NVMe drives: adds lanes, and (per direction) speed is calculated with
|
|
lane speed * lanes * PCIe overhead. PCIe 1 and 2 have data rates of
|
|
GT/s * .8 = Gb/s (10 bits required to transfer 8 bits of data).
|
|
PCIe 3 and greater transfer data at a rate of GT/s * 128/130 * lanes = Gb/s
|
|
(130 bits required to transfer 128 bits of data).
|
|
|
|
For a PCIe 3 NVMe drive, with speed of \fB8 GT/s\fR and \fB4\fR lanes
|
|
(\fB8GT/s * 128/130 * 4 = 31.6 Gb/s\fR):
|
|
|
|
\fBspeed: 31.6 Gb/s lanes: 4\fR
|
|
|
|
.TP
|
|
.B \-xx \-G\fR
|
|
\- Adds vendor:product ID of each Graphics card.
|
|
|
|
\- Adds Xorg compositor, if found (always shows for Wayland systems).
|
|
|
|
\- For free drivers, adds OpenGL compatibility version number if available.
|
|
For nonfree drivers, the core version and compatibility versions are usually
|
|
the same. Example:
|
|
|
|
\fBv: 3.3 Mesa 11.2.0 compat\-v: 3.0\fR
|
|
|
|
\- If available, shows \fBalternate:\fR Xorg drivers. This means a driver on
|
|
the default list of drivers Xorg automatically checks for the card, but which
|
|
is not installed. For example, if you have \fBnouveau\fR driver, \fBnvidia\fR would
|
|
show as alternate if it was not installed. Note that \fBalternate:\fR does NOT mean you
|
|
should have it, it's just one of the drivers Xorg checks to see if is present
|
|
and loaded when checking the card. This can let you know there are other driver options.
|
|
Note that if you have explicitly set the driver in \fBxorg.conf\fR, Xorg will not
|
|
create this automatic check driver list.
|
|
|
|
\- If available, shows Xorg dpi (\fBs-dpi:\fR) for the active Xorg \fBScreen\fR
|
|
(not physical monitor). Note that the physical monitor dpi and the Xorg
|
|
dpi are not necessarily the same thing, and can vary widely.
|
|
|
|
.TP
|
|
.B \-xx \-I\fR
|
|
\- Adds init type version number (and rc if present).
|
|
|
|
\- Adds other detected installed gcc versions (if present).
|
|
|
|
\- Adds system default runlevel, if detected. Supports Systemd/Upstart/SysVinit
|
|
type defaults.
|
|
|
|
\- Adds parent program (or tty) that started shell, if not IRC client.
|
|
|
|
.TP
|
|
.B \-xx \-j\fR (\fB\-\-swap\fR), \fB\-xx \-p\fR, \fB\-xx \-P\fR
|
|
\- Adds swap priority to each swap partition (for \fB\-P\fR) used, and for all
|
|
swap types (for \fB\-j\fR).
|
|
|
|
.TP
|
|
.B \-xx \-J\fR (\fB\-\-usb\fR)
|
|
\- Adds vendor:chip id.
|
|
|
|
.TP
|
|
.B \-xx \-m\fR, \fB\-\-memory\-modules\fR
|
|
\- Adds memory device Manufacturer.
|
|
|
|
\- Adds memory device Part Number (\fBpart\-no:\fR). Useful for ordering new or
|
|
replacement memory sticks etc. Part numbers are unique, particularly
|
|
if you use the word \fBmemory\fR in the search as well. With \fB\-xxx\fR,
|
|
also shows serial number.
|
|
|
|
\- Adds single/double bank memory, if data is found. Note, this may not be 100% right
|
|
all of the time since it depends on the order that data is found in \fBdmidecode\fR
|
|
output for \fBtype 6\fR and \fBtype 17\fR.
|
|
|
|
.TP
|
|
.B \-xx \-M\fR
|
|
\- Adds chassis information, if data is available. Also shows BIOS
|
|
ROM size if using \fBdmidecode\fR.
|
|
|
|
.TP
|
|
.B \-xx \-N\fR
|
|
\- Adds vendor:product ID for each Network card.
|
|
|
|
.TP
|
|
.B \-xx \-R\fR
|
|
\- md\-raid: Adds superblock (if present) and algorithm. If resync,
|
|
shows progress bar.
|
|
|
|
\- Hardware RAID: Adds Chip vendor:product ID.
|
|
|
|
.TP
|
|
.B \-xx \-s\fR
|
|
\- Adds DIMM/SOC voltages, if present (\fBipmi\fR only).
|
|
|
|
.TP
|
|
.B \-xx \-S\fR
|
|
\- Adds display manager (\fBdm\fR) type, if present. If none, shows N/A.
|
|
Supports most known display managers, including gdm, gdm3,
|
|
idm, kdm, lightdm, lxdm, mdm, nodm, sddm, slim, tint, wdm, and xdm.
|
|
|
|
\- Adds, if run in X, window manager type (\fBwm\fR), if available.
|
|
Not all window managers are supported. Some desktops support using more than one
|
|
window manager, so this can be useful to see what window manager is actually running.
|
|
If none found, shows nothing. Uses a less accurate fallback tool \fBwmctrl\fR
|
|
if \fBps\fR tests fail to find data.
|
|
|
|
\- Adds desktop toolkit (\fBtk\fR), if available (Xfce/KDE/Trinity).
|
|
|
|
.TP
|
|
.B \-xx \-\-slots\fR
|
|
\- Adds slot length.
|
|
|
|
.TP
|
|
.B \-xx \-w\fR,\fB \-W\fR
|
|
\- Adds wind chill, heat index, and dew point, if available.
|
|
|
|
\- Adds cloud cover, rain, snow, or precipitation (amount in previous hour
|
|
to observation time), if available.
|
|
|
|
.TP
|
|
.B \-xxx \-A\fR
|
|
\- Adds, if present, serial number.
|
|
|
|
.TP
|
|
.B \-xxx \-B\fR
|
|
\- Adds battery chemistry (e.g. \fBLi\-ion\fR), cycles (NOTE: there appears to
|
|
be a problem with the Linux kernel obtaining the cycle count, so this almost
|
|
always shows \fB0\fR. There's nothing that can be done about this glitch, the
|
|
data is simply not available as of 2018\-04\-03), location (only available from
|
|
\fBdmidecode\fR derived output).
|
|
|
|
\- Adds attached device \fBrechargeable: [yes|no]\fR information.
|
|
|
|
.TP
|
|
.B \-xxx \-C\fR
|
|
\- Adds \fBboost: [enabled|disabled]\fR if detected, aka \fBturbo\fR. Not all CPUs
|
|
have this feature.
|
|
|
|
.TP
|
|
.B \-xxx \-D\fR
|
|
\- Adds disk firmware revision number (if available).
|
|
|
|
\- Adds disk partition scheme (in most cases), e.g. \fBscheme: GPT\fR. Currently not
|
|
able to detect all schemes, but handles the most common, e.g. \fBGPT\fR or \fBMBR\fR.
|
|
|
|
\- Adds disk rotation speed (in some but not all cases), e.g. \fBrotation: 7200 rpm\fR.
|
|
Only appears if detected (SSD drives do not have rotation speeds, for example). If none
|
|
found, nothing shows. Not all disks report this speed, so even if they are spinnning,
|
|
no data will show.
|
|
|
|
.TP
|
|
.B \-xxx \-G\fR
|
|
\- Adds (if available) Xorg \fBcompositor:\fR version \fBv:\fR (always shows if
|
|
found for Wayland systems).
|
|
|
|
.TP
|
|
.B \-xxx \-I\fR
|
|
\- For \fBShell:\fR adds \fB(su|sudo|login)\fR to shell name if present.
|
|
|
|
\- For \fBrunning in:\fR adds \fB(SSH)\fR to parent, if present. SSH detection
|
|
uses the \fBwho am i\fR test.
|
|
|
|
.TP
|
|
.B \-xxx \-J\fR (\fB\-\-usb\fR)
|
|
\- Adds, if present, serial number for non hub devices.
|
|
|
|
\- Adds \fBinterfaces:\fR for non hub devices.
|
|
|
|
\- Adds, if available, USB speed in \fBMbits/s\fR or \fBGbits/s\fR.
|
|
|
|
.TP
|
|
.B \-xxx \-m\fR, \fB\-\-memory\-modules\fR
|
|
\- Adds memory bus width: primary bus width, and if present, total width. e.g.
|
|
\fBbus width: 64 bit (total: 72 bits)\fR. Note that total / data widths are mixed up
|
|
sometimes in dmidecode output, so inxi will take the larger value as the total if
|
|
present. If no total width data is found, then inxi will not show that item.
|
|
|
|
\- Adds device Type Detail, e.g. \fBdetail: DDR3 (Synchronous)\fR.
|
|
|
|
\- Adds, if present, memory module voltage. Only some systems will have this
|
|
data available.
|
|
|
|
\- Adds device serial number.
|
|
|
|
.TP
|
|
.B \-xxx \-N\fR
|
|
\- Adds, if present, serial number.
|
|
|
|
.TP
|
|
.B \-xxx \-R\fR
|
|
\- md\-raid: Adds system mdraid support types (kernel support, read ahead, RAID events)
|
|
|
|
\- zfs\-raid: Adds portion allocated (used) by RAID array/device.
|
|
|
|
\- Hardware RAID: Adds rev, ports, and (if available and/or relevant)
|
|
\fBvendor:\fR item, which shows specific vendor [product] information.
|
|
|
|
.TP
|
|
.B \-xxx \-S\fR
|
|
\- Adds, if in X, or with \fB--display\fR, bar/dock/panel/tray items
|
|
(\fBinfo\fR). If none found, shows nothing. Supports desktop items like gnome\-panel,
|
|
lxpanel, xfce4\-panel, lxqt\-panel, tint2, cairo-dock, trayer, and many others.
|
|
|
|
\- Adds (if present), window manager (\fBwm\fR) version number.
|
|
|
|
\- Adds (if present), display manager (\fBdm\fR) version number.
|
|
|
|
.TP
|
|
.B \-xxx \-w\fR,\fB \-W\fR
|
|
\- Adds location (city state country), observation altitude (if available),
|
|
weather observation time (if available), sunset/sunrise (if available).
|
|
|
|
.SH ADMIN EXTRA DATA OPTIONS
|
|
These options are triggered with \fB\-\-admin\fR or \fB\-a\fR. Admin options are
|
|
advanced output options, and are more technical, and mostly of interest to system
|
|
administrators or other machine admins.
|
|
|
|
The \fB\-\-admin\fR option sets \fB\-xxx\fR, and only has to be used once.
|
|
It will trigger the following features:
|
|
|
|
.TP
|
|
.B \-a \-C\fR
|
|
\- Adds CPU family, model\-id, and stepping (replaces \fBrev\fR of \fB\-Cx\fR).
|
|
Format is \fBhexadecimal (decimal)\fR if greater than 9, otherwise \fBhexadecimal\fR.
|
|
|
|
\- Adds CPU microcode. Format is \fBhexadecimal\fR.
|
|
|
|
\- Adds CPU Vulnerabilities (bugs) as known by your current kernel. Lists by
|
|
\fBType: ... (status|mitigation): ....\fR for systems that support this feature
|
|
(Linux kernel 4.14 or newer, or patched older kernels).
|
|
|
|
.TP
|
|
.B \-a \-d\fR,\fB\-a \-D\fR
|
|
\- Adds logical and physical block size in bytes.
|
|
|
|
Using \fBsmartctl\fR (requires sudo/root privileges).
|
|
|
|
\- Adds device model family, like \fBCaviar Black\fR, if available.
|
|
|
|
\- Adds SATA type (eg 1.0, 2.6, 3.0) if a SATA device.
|
|
|
|
\- Adds SMART report line: status, enabled/disabled, health, powered on,
|
|
cycles, and some error cases if out of range values. Note that for Pre\-fail items,
|
|
it will show the VALUE and THRESHOLD numbers. It will also fall back for unknown
|
|
attributes that are or have been failing and print out the Attribute name, value,
|
|
threshold, and failing message. This way even for unhandled Attribute names,
|
|
you should get a solid report for full failure cases. Other cases may show
|
|
if inxi believes that the item may be approaching failure. This is a guess so
|
|
make sure to check the drive and smartctl full output to verify before
|
|
taking any further action.
|
|
|
|
\- Adds, for USB or other external drives, actual model name/serial if
|
|
available, and different from enclosure model/serial, and corrects block
|
|
sizes if necessary. Adds in drive temperature for some drives as well,
|
|
and other useful data.
|
|
|
|
.TP
|
|
.B \-a \-G\fR
|
|
Triggers a much more complete Screen/Monitor output on the
|
|
\fBDisplay:\fR line of \fB\-G\fR. Note that the
|
|
basic feature requires \fBxdpyinfo\fR, and the advanced per monitor
|
|
feature requires \fBxrandr\fR.
|
|
|
|
No support currently exists for \fBWayland\fR since we so far can find
|
|
no documentation or easy methods to extract this information from \fBWayland\fR
|
|
compositors. This unfortunate situation may change in the future, hopefully.
|
|
However, most \fBWayland\fR systems also come with \fBxwayland\fR,
|
|
which should supply the tools necessary for the time being.
|
|
|
|
Further note that all references to \fBDisplays\fR, \fBScreens\fR,
|
|
and \fBMonitors\fR are referring to the \fBX\fR technical terms,
|
|
not normal consumer usage. 1 \fBDisplay\fR runs 1 or more
|
|
\fBScreens\fR, and a \fBScreen\fR runs 1 or more \fBMonitors\fR.
|
|
|
|
\- Adds \fBDisplay\fR ID, for the Display running the Screen that runs the Monitors.
|
|
|
|
\- Adds total number of \fBScreens\fR listed for the current \fBDisplay\fR.
|
|
|
|
\- Adds default \fBScreen\fR ID if Screen (not monitor!) total is greater than 1.
|
|
|
|
\- Adds \fBScreen\fR line, which includes the ID (\fBScreen: 0\fR) then \fBs-res\fR
|
|
(Screen resolution), \fBs\-dpi\fR, \fBs\-size\fR and \fBs\-diag\fR. Remember, this is an
|
|
Xorg \fBScreen\fR, NOT a monitor screen, and the information listed is about
|
|
the Xorg Screen! It may at times be the same as a single monitor system,
|
|
but usually it's different in some ways.
|
|
|
|
\- Adds \fBMonitor\fR ID(s). Monitors are a subset of a Screen, each of which
|
|
can have one or more monitors. Normally a dual monitor setup is 2 monitors
|
|
run by one Xorg Screen. Each monitor has the following data, if available:
|
|
|
|
\- \fBres:\fR resolution in pixels. This is the individual monitor's
|
|
reported pixel dimensions.
|
|
|
|
\- \fBhz:\fR frequency in Herz, as reported to Xorg. Note that there have been
|
|
and may continue to be bugs with how Xorg treats > 1 monitor frequencies.
|
|
|
|
\- \fBdpi:\fR dpi (dots per inch), aka, ppi (pixels per inch). This is the
|
|
physical screen dpi, which is calculated using the screen dimensions and its
|
|
resolution.
|
|
|
|
\- \fBsize:\fR size in mm (inches). Note that this is the real monitor size,
|
|
not the Xorg Screen size, which can be quite different (1 Xorg Screen can
|
|
for instance contain two or more monitors).
|
|
|
|
\- \fBdiag:\fR monitor screen diagonal in mm (inches). Note that this is
|
|
the real monitor size, not the Xorg full Screen diagonal size, which
|
|
can be quite different.
|
|
|
|
Sample (with both \fBxdpyinfo\fR and \fBxrandr\fR data available):
|
|
.nf
|
|
\fBinxi \-aG
|
|
Graphics:
|
|
....
|
|
Display: x11 server: X.Org 1.20.6 driver: modesetting
|
|
display ID: :0.0 screens: 1
|
|
Screen\-1: 0 s\-res: 2560x1024 s\-dpi: 96 s\-size: 677x271mm (26.7x10.7")
|
|
s\-diag: 729mm (28.7")
|
|
Monitor\-1: DVI\-I\-0 res: 1280x1024 hz: 60 dpi: 96
|
|
size: 338x270mm (13.3x10.6") diag: 433mm (17")
|
|
Monitor\-2: VGA\-0 res: 1280x1024 hz: 60 dpi: 86
|
|
size: 376x301mm (14.8x11.9") diag: 482mm (19")
|
|
....
|
|
.fi
|
|
|
|
.TP
|
|
.B \-a \-j\fR, \fB\-a \-P\fR , \fB\-a \-P\fR
|
|
\- Adds swappiness and vfs cache pressure, and a message to indicate
|
|
if the value is the default value or not (Linux only, and only if available).
|
|
If not the default value, shows default value as well, e.g.
|
|
|
|
For \fB\-P\fR per swap physical partition:
|
|
|
|
\fBswappiness: 60 (default) cache pressure: 90 (default 100)\fR
|
|
|
|
For \fB\-j\fR row 1 output:
|
|
|
|
\fBKernel: swappiness: 60 (default) cache pressure: 90 (default 100)\fR
|
|
|
|
.TP
|
|
.B \-a \-p\fR,\fB\-a \-P\fR
|
|
\- Adds raw partition size, including file system overhead, partition table, e.g.
|
|
|
|
\fBraw size: 60.00 GiB\fR.
|
|
|
|
\- Adds percent of raw size available to \fBsize:\fR item, e.g.
|
|
|
|
\fBsize: 58.81 GiB (98.01%)\fR.
|
|
|
|
Note that \fBused: 16.44 GiB (34.3%)\fR percent refers to the available size,
|
|
not the raw size.
|
|
|
|
\- Adds partition filesystem block size if found (requires root and blockdev).
|
|
|
|
.TP
|
|
.B \-a \-S\fR
|
|
\- Adds kernel boot parameters to \fBKernel\fR section (if detected). Support
|
|
varies by OS type.
|
|
|
|
.SH ADVANCED OPTIONS
|
|
|
|
.TP
|
|
.B \-\-alt 40\fR
|
|
Bypass \fBPerl\fR as a downloader option. Priority is: Perl (HTTP::Tiny),
|
|
Curl, Wget, Fetch, (OpenBSD only) ftp.
|
|
|
|
.TP
|
|
.B \-\-alt 41\fR
|
|
Bypass \fBCurl\fR as a downloader option. Priority is: Perl (HTTP::Tiny),
|
|
Curl, Wget, Fetch, (OpenBSD only) ftp.
|
|
|
|
.TP
|
|
.B \-\-alt 42\fR
|
|
Bypass \fBFetch\fR as a downloader option. Priority is: Perl (HTTP::Tiny),
|
|
Curl, Wget, Fetch, (OpenBSD only) ftp.
|
|
|
|
.TP
|
|
.B \-\-alt 43\fR
|
|
Bypass \fBWget\fR as a downloader option. Priority is: Perl (HTTP::Tiny),
|
|
Curl, Wget, Fetch, OpenBSD only: ftp
|
|
|
|
.TP
|
|
.B \-\-alt 44\fR
|
|
Bypass \fBCurl\fR, \fBFetch\fR, and \fBWget\fR as downloader options. This
|
|
basically forces the downloader selection to use \fBPerl 5.x\fR \fBHTTP::Tiny\fR,
|
|
which is generally slower than \fBCurl\fR or \fBWget\fR but it may help bypass
|
|
issues with downloading.
|
|
|
|
.TP
|
|
.B \-\-dig\fR
|
|
Temporary override of \fBNO_DIG\fR configuration item. Only use to test w/wo dig.
|
|
Restores default behavior for WAN IP, which is use dig if present.
|
|
|
|
.TP
|
|
.B \-\-display [:<integer>]\fR
|
|
Will try to get display data out of X (does not usually work as root user).
|
|
Default gets display info from display \fB:0\fR. If you use the format
|
|
\fB\-\-display :1\fR then it would get it from display \fB1\fR instead,
|
|
or any display you specify.
|
|
|
|
Note that in some cases, \fB\-\-display\fR will cause inxi to hang endlessly when
|
|
running the option in console with Intel graphics. The situation regarding
|
|
other free drivers such as nouveau/ATI is currently unknown. It may be that
|
|
this is a bug with the Intel graphics driver \- more information is required.
|
|
|
|
You can test this easily by running the following command out of X/display server:
|
|
\fBglxinfo \-display :0\fR
|
|
|
|
If it hangs, \fB\-\-display\fR will not work.
|
|
|
|
.TP
|
|
.B \-\-dmidecode\fR
|
|
Force use of \fBdmidecode\fR. This will override \fB/sys\fR data in some lines,
|
|
e.g. \fB\-M\fR or \fB\-B\fR.
|
|
|
|
.TP
|
|
.B \-\-downloader [curl|fetch|perl|wget]\fR
|
|
Force inxi to use Curl, Fetch, Perl, or Wget for downloads.
|
|
|
|
.TP
|
|
.B \-\-host\fR
|
|
Turns on hostname in System line. Overrides inxi config file value (if set):
|
|
|
|
\fBSHOW_HOST='false'\fR \- Same as: \fBSHOW_HOST='true'\fR
|
|
|
|
This is an absolute override, the host will always show no matter what
|
|
other switches you use.
|
|
|
|
.TP
|
|
.B \-\-indent\-min [integer]\fR
|
|
Overrides default indent minimum value. This is the value that makes inxi change from
|
|
wrapped line starters [like \fBInfo\fR] to non wrapped. If less than \fB80\fR,
|
|
no wrapping will occur. Overrides internal default value and user configuration value:
|
|
|
|
\fBINDENT_MIN=85\fR
|
|
|
|
.TP
|
|
.B \-\-limit [\-1 \- x]\fR
|
|
Raise or lower max output limit of IP addresses for \fB\-i\fR. \fB\-1\fR removes limit.
|
|
|
|
.TP
|
|
.B \-\-man\fR
|
|
Updates / installs man page with \fB\-U\fR if \fBpinxi\fR or using \fB\-U 3\fR dev branch.
|
|
(Only active if \fB\-U\fR is is not disabled by maintainers).
|
|
|
|
.TP
|
|
.B \-\-no\-dig\fR
|
|
Overrides default use of \fBdig\fR to get WAN IP address. Allows use of normal
|
|
downloader tool to get IP addresses. Only use if dig is failing, since dig is much
|
|
faster and more reliable in general than other methods.
|
|
|
|
.TP
|
|
.B \-\-no\-host\fR
|
|
Turns off hostname in System line. This is default when using \fB\-z\fR,
|
|
for anonymizing inxi output for posting on forums or IRC. Overrides
|
|
configuration value (if set):
|
|
|
|
\fBSHOW_HOST='true'\fR \- Same as: \fBSHOW_HOST='false'\fR
|
|
|
|
This is an absolute override, the host will not show no matter what other
|
|
switches you use.
|
|
|
|
.TP
|
|
.B \-\-no\-man\fR
|
|
Disables man page install with \fB\-U\fR for master and active development branches.
|
|
(Only active if \fB\-U\fR is is not disabled by maintainers).
|
|
|
|
.TP
|
|
.B \-\-no\-ssl\fR
|
|
Skip SSL certificate checks for all downloader actions (\fB\-U\fR, \fB\-w\fR,
|
|
\fB\-W\fR, \fB\-i\fR). Use if your system does not have current SSL certificate
|
|
lists, or if you have problems making a connection for any reason. Works with
|
|
\fBWget\fR, \fBCurl\fR, \fBPerl HTTP::Tiny\fRand \fBFetch\fR.
|
|
|
|
.TP
|
|
.B \-\-no\-sudo\fR
|
|
Skips the use of sudo to run certain internal features (like \fBhddtemp\fR, \fBfile\fR)
|
|
with sudo. Not related to running inxi itself with sudo or super user. Some systems will
|
|
register errors which will then trigger admin emails in such cases, so if you want to disable
|
|
regular user use of sudo (which requires configuration to setup anyway for these options)
|
|
just use this option, or \fBNO_SUDO\fR configuration item.
|
|
|
|
.TP
|
|
.B \-\-output [json|screen|xml]\fR
|
|
Change data output type. Requires \-\-output\-file if not \fBscreen\fR.
|
|
|
|
.TP
|
|
.B \-\-output\-file [full path to output file|print]\fR
|
|
The given directory path must exist. The directory path given must exist,
|
|
The \fBprint\fR options prints to stdout.
|
|
Required for non\-screen \fB\-\-output\fR formats (json|xml).
|
|
|
|
.TP
|
|
.B \-\-partition\-sort [dev\-base|fs|id|label|percent\-used|size|uuid|used]\fR
|
|
Change default sort order of partition output. Corresponds to \fBPARTITION_SORT\fR
|
|
configuration item. These are the available sort options:
|
|
|
|
\fBdev\-base\fR - \fB/dev\fR partition identifier, like \fB/dev/sda1\fR.
|
|
Note that it's an alphabetic sort, so \fBsda12\fR is before \fBsda2\fR.
|
|
|
|
\fBfs\fR \- Partition filesystem. Note that sorts will be somewhat random if all
|
|
filesystems are the same.
|
|
|
|
\fBid\fR \- Mount point of partition (default).
|
|
|
|
\fBlabel\fR \- Label of partition. If partitions have no labels,
|
|
sort will be random.
|
|
|
|
\fBpercent\-used\fR - Percentage of partition size used.
|
|
|
|
\fBsize\fR \- KiB size of partition.
|
|
|
|
\fBuuid\fR \- UUID of the partition.
|
|
|
|
\fBused\fR \- KiB used of partition.
|
|
|
|
.TP
|
|
.B \-\-pm\-type [package manager name]\fR
|
|
For distro package maintainers only, and only for non apt, rpm, or pacman based systems.
|
|
To be used to test replacement package lists for recommends for that package manager.
|
|
|
|
.TP
|
|
.B \-\-sleep [0\-x.x]\fR
|
|
Usually in decimals. Change CPU sleep time for \fB\-C\fR (current: \fB\0.35\fR).
|
|
Sleep is used to let the system catch up and show a more accurate CPU use. Example:
|
|
|
|
\fBinxi \-Cxxx \-\-sleep 0.15\fR
|
|
|
|
Overrides default internal value and user configuration value:
|
|
|
|
\fBCPU_SLEEP=0.25\fR
|
|
|
|
.TP
|
|
.B \-\-tty\fR
|
|
Forces internal IRC flag to off. Used in unhandled cases where the program running
|
|
inxi may not be seen as a shell/tty, but it is not an IRC client. Put \fB\-\-tty\fR
|
|
first in option list to avoid unexpected errors. If you want a specific
|
|
output width, use the \fB\-\-width\fR option. If you want normal color codes in
|
|
the output, use the \fB\-c [color ID]\fR flag.
|
|
|
|
The sign you need to use this is extra numbers before the key/value pairs of the
|
|
output of your program. These are IRC, not TTY, color codes. Please post a github
|
|
issue if you find you need to use \fB\-\-tty\fR (including the full
|
|
\fB\-Ixxx\fR line) so we can figure out how to add your program to the list
|
|
of whitelisted programs.
|
|
|
|
You can see what inxi believed started it in the \fB\-Ixxx\fR line, \fBShell:\fR or
|
|
\fBClient:\fR item. Please let us know what that result was so we can add it to the
|
|
parent start program whitelist.
|
|
|
|
.TP
|
|
.B \-\-usb\-sys\fR
|
|
Forces the USB data generator to use \fB/sys\fR as data source
|
|
instead of \fBlsusb\fR.
|
|
|
|
.TP
|
|
.B \-\-usb\-tool\fR
|
|
Forces the USB data generator to use \fBlsusb\fR as data source. Overrides
|
|
\fBUSB_SYS\fR in user configuration file(s).
|
|
|
|
.TP
|
|
.B \-\-wan\-ip\-url [URL]\fR
|
|
Force \fB\-i\fR to use supplied URL as WAN IP source. Overrides dig or
|
|
default IP source urls. URL must start with http[s] or ftp.
|
|
|
|
The IP address from the URL must be the last item on the last (non\-empty) line
|
|
of the page content source code.
|
|
|
|
Same as configuration value (example):
|
|
|
|
\fBWAN_IP_URL='https://mysite.com/ip.php'\fR
|
|
|
|
.TP
|
|
.B \-\-wm\fR
|
|
Force \fBSystem\fR item \fBwm\fR to use \fBwmctrl\fR as data source,
|
|
override default \fBps\fR source.
|
|
|
|
.SH DEBUGGING OPTIONS
|
|
|
|
.TP
|
|
.B \-\-dbg 1\fR
|
|
\- Debug downloader failures. Turns off silent/quiet mode for curl, wget, and
|
|
fetch. Shows more downloader action information. Shows some more information
|
|
for Perl downloader.
|
|
|
|
.TP
|
|
.B \-\-dbg [2\-xx]\fR
|
|
\- See github \fBinxi-perl/docs/inxi-values.txt\fR for specific specialized debugging
|
|
options. These can vary but tend to not change much, though they are added as
|
|
needed.
|
|
|
|
.TP
|
|
.B \-\-debug [1\-3]\fR
|
|
\- On screen debugger output. Output varies depending on current needs
|
|
Usually nothing changes.
|
|
|
|
.TP
|
|
.B \-\-debug 10\fR
|
|
\- Basic logging. Check \fB$XDG_DATA_HOME/inxi/inxi.log\fR or
|
|
\fB$HOME/.local/share/inxi/inxi.log\fR or \fB$HOME/.inxi/inxi.log\fR.
|
|
|
|
.TP
|
|
.B \-\-debug 11\fR
|
|
\- Full file/system info logging.
|
|
|
|
.TP
|
|
.B \-\-debug 20\fR
|
|
Creates a tar.gz file of system data and collects the inxi output
|
|
in a file.
|
|
|
|
* tree traversal data file(s) read from \fB/proc\fR and \fB/sys\fR, and
|
|
other system data.
|
|
|
|
* xorg conf and log data, xrandr, xprop, xdpyinfo, glxinfo etc.
|
|
|
|
* data from dev, disks, partitions, etc.
|
|
|
|
.TP
|
|
.B \-\-debug 21\fR
|
|
Automatically uploads debugger data tar.gz file to \fIftp.techpatterns.com\fR,
|
|
then removes the debug data directory, but leaves the debug tar.gz file.
|
|
See \fB\-\-ftp\fR for uploading to alternate locations.
|
|
|
|
.TP
|
|
.B \-\-debug 22\fR
|
|
Automatically uploads debugger data tar.gz file to \fIftp.techpatterns.com\fR, then
|
|
removes the debug data directory and the tar.gz file.
|
|
See \fB\-\-ftp\fR for uploading to alternate locations.
|
|
|
|
.TP
|
|
.B \-\-ftp [ftp.yoursite.com/incoming]\fR
|
|
For alternate ftp upload locations: Example:
|
|
|
|
\fBinxi \-\-ftp \fIftp.yourserver.com/incoming\fB \-\-debug 21\fR
|
|
|
|
.SH DEBUGGING OPTIONS TO DEBUG DEBUGGER FAILURES
|
|
|
|
Only used the following in conjunction with \fB\-\-debug 2[012]\fR, and only
|
|
use if you experienced a failure or hang, or were instructed to do so.
|
|
|
|
.TP
|
|
.B \-\-debug\-proc\fR
|
|
Force debugger to parse \fB/proc\fR directory data when run as root. Normally this is
|
|
disabled due to unpredictable data in /proc tree.
|
|
|
|
.TP
|
|
.B \-\-debug\-proc\-print\fR
|
|
Use this to locate file that /proc debugger hangs on.
|
|
|
|
.TP
|
|
.B \-\-debug\-no\-exit\fR
|
|
Skip exit on error when running debugger.
|
|
|
|
.TP
|
|
.B \-\-debug\-no\-proc\fR
|
|
Skip /proc debugging in case of a hang.
|
|
|
|
.TP
|
|
.B \-\-debug\-no\-sys\fR
|
|
Skip /sys debugging in case of a hang.
|
|
|
|
.TP
|
|
.B \-\-debug\-sys\fR
|
|
Force PowerPC debugger parsing of /sys as sudo/root.
|
|
|
|
.TP
|
|
.B \-\-debug\-sys\-print\fR
|
|
Use this to locate file that /sys debugger hangs on.
|
|
|
|
.SH SUPPORTED IRC CLIENTS
|
|
BitchX, Gaim/Pidgin, ircII, Irssi, Konversation, Kopete, KSirc, KVIrc, Weechat,
|
|
and Xchat. Plus any others that are capable of displaying either built\-in or external
|
|
script output.
|
|
|
|
.SH RUNNING IN IRC CLIENT
|
|
To trigger inxi output in your IRC client, pick the appropriate method from the
|
|
list below:
|
|
.TP
|
|
.B Hexchat, XChat, Irssi
|
|
\fR(and many other IRC clients)
|
|
.B /exec \-o inxi \fR[\fBoptions\fR]
|
|
If you don't include the \fB\-o\fR, only you will see the output on your local
|
|
IRC client.
|
|
.TP
|
|
.B Konversation
|
|
.B /cmd inxi
|
|
\fR[\fBoptions\fR]
|
|
|
|
To run inxi in Konversation as a native script if your distribution or inxi package
|
|
hasn't already done this for you, create this symbolic link:
|
|
|
|
KDE 4:
|
|
.B ln \-s /usr/local/bin/inxi /usr/share/kde4/apps/konversation/scripts/inxi
|
|
|
|
KDE 5:
|
|
.B ln \-s /usr/local/bin/inxi /usr/share/konversation/scripts/inxi
|
|
|
|
If inxi is somewhere else, change the path \fB/usr/local/bin\fR to wherever it
|
|
is located.
|
|
|
|
If you are using KDE/QT 5, then you may also need to add the following to get
|
|
the Konversation \fR/inxi\fR command to work:
|
|
|
|
.B ln \-s /usr/share/konversation /usr/share/apps/
|
|
|
|
Then you can start inxi directly, like this:
|
|
|
|
.B /inxi
|
|
\fR[\fBoptions\fR]
|
|
.TP
|
|
.B WeeChat
|
|
.B NEW: /exec \-o inxi
|
|
\fR[\fBoptions\fR]
|
|
|
|
.B OLD: /shell \-o inxi
|
|
\fR[\fBoptions\fR]
|
|
|
|
Newer (2014 and later) WeeChats work pretty much the same now as other console
|
|
IRC clients, with \fB/exec \-o inxi \fR[\fBoptions\fR]. Newer WeeChats
|
|
have dropped the \fB\-curses\fR part of their program name, i.e.:
|
|
\fBweechat\fR instead of \fBweechat\-curses\fR.
|
|
|
|
.SH CONFIGURATION FILE
|
|
inxi will read its configuration/initialization files in the
|
|
following order:
|
|
|
|
\fB/etc/inxi.conf\fR contains the default configurations. These can be overridden
|
|
by user configurations found in one of the following locations (inxi will
|
|
store its config file using the following precedence:
|
|
if \fB$XDG_CONFIG_HOME\fR is not empty, it will go there, else if
|
|
\fB$HOME/.conf/inxi.conf\fR exists, it will go there, and as a last default,
|
|
the legacy location is used), i.e.:
|
|
|
|
\fB$XDG_CONFIG_HOME/inxi.conf\fR > \fB$HOME/.conf/inxi.conf\fR >
|
|
\fB$HOME/.inxi/inxi.conf\fR
|
|
|
|
.SH CONFIGURATION OPTIONS
|
|
|
|
See the documentation page for more complete information on how to set
|
|
these up, and for a complete list of options:
|
|
|
|
.I https://smxi.org/docs/inxi\-configuration.htm
|
|
.TP
|
|
.B Basic Options
|
|
Here's a brief overview of the basic options you are likely to want to use:
|
|
|
|
\fBCOLS_MAX_CONSOLE\fR The max display column width on terminal.
|
|
|
|
\fBCOLS_MAX_IRC\fR The max display column width on IRC clients.
|
|
|
|
\fBCOLS_MAX_NO_DISPLAY\fR The max display column width in console, out of GUI desktop.
|
|
|
|
\fBCPU_SLEEP\fR Decimal value \fB0\fR or more. Default is usually around \fB0.35\fR
|
|
seconds. Time that inxi will 'sleep' before getting CPU speed data, so that it
|
|
reflects actual system state.
|
|
|
|
\fBDOWNLOADER\fR Sets default inxi downloader: curl, fetch, ftp, perl, wget.
|
|
See \fB\-\-recommends\fR output for more information on downloaders and Perl downloaders.
|
|
|
|
\fBFILTER_STRING\fR Default \fB<filter>\fR. Any string you prefer to see instead
|
|
for filtered values.
|
|
|
|
\fBINDENT_MIN\fR The point where the line starter wrapping to its own line happens.
|
|
Overrides default. See \fB\-\-indent\-min\fR. If \fB80\fR or less, wrap will never happen.
|
|
|
|
\fBLIMIT\fR Overrides default of \fB10\fR IP addresses per IF. This is only of interest
|
|
to sys admins running servers with many IP addresses.
|
|
|
|
\fBNO_DIG\fR Set to \fB1\fR or \fBtrue\fR to disable WAN IP use of \fBdig\fR and force
|
|
use of alternate downloaders.
|
|
|
|
\fBNO_SUDO\fR Set to \fB1\fR or \fBtrue\fR to disable internal use of \fBsudo\fR.
|
|
|
|
\fBPARTITION_SORT\fR Overrides default partition output sort. See
|
|
\fB\-\-partition\-sort\fR for options.
|
|
|
|
\fBPS_COUNT\fR The default number of items showing per \fB\-t\fR type, \fBm\fR or
|
|
\fBc\fR. Default is 5.
|
|
|
|
\fBSENSORS_CPU_NO\fR In cases of ambiguous temp1/temp2 (inxi can't figure out which
|
|
is the CPU), forces sensors to use either value 1 or 2 as CPU temperature. See the
|
|
above configuration page on smxi.org for full info.
|
|
|
|
\fBSEP2_CONSOLE\fR Replaces default key / value separator of '\fB:\fR'.
|
|
|
|
\fBUSB_SYS\fR Forces all USB data to use \fB/sys\fR instead of \fBlsusb\fR.
|
|
|
|
\fBWAN_IP_URL\fR Forces \fB\-i\fR to use supplied URL, and to not use dig (dig is
|
|
generally much faster). URL must begin with http or ftp. Note that if you use this,
|
|
the downloader set tests will run each time you start inxi whether a downloader feature
|
|
is going to be used or not.
|
|
|
|
The IP address from the URL must be the last item on the last (non\-empty) line of
|
|
the URL's page content source code.
|
|
|
|
Same as \fB\-\-wan\-ip\-url [URL]\fR
|
|
|
|
\fBWEATHER_SOURCE\fR Values: [\fB0-9\fR]. Same as \fB\-\-weather\-source\fR. Values
|
|
4\-9 are not currently supported, but this can change at any time.
|
|
|
|
\fBWEATHER_UNIT\fR Values: [\fBc\fR|\fBf\fR|\fBcf\fR|\fBfc\fR]. Same as \fB\-\-weather\-unit\fR.
|
|
|
|
.TP
|
|
.B Color Options
|
|
It's best to use the \fB\-c [94\-99]\fR color selector tool to set the following values
|
|
because it will correctly update the configuration file and remove any invalid
|
|
or conflicting items, but if you prefer to create your own configuration files,
|
|
here are the options. All take the integer value from the options available in
|
|
\fB\-c 94\-99\fR.
|
|
|
|
NOTE: All default and configuration file set color values are removed when output is
|
|
piped or redirected. You must use the explicit \fB\-c <color number>\fR option
|
|
if you want colors to be present in the piped/redirected output (creating a PDF for
|
|
example).
|
|
|
|
\fBCONSOLE_COLOR_SCHEME\fR The color scheme for console output (not in X/Wayland).
|
|
|
|
\fBGLOBAL_COLOR_SCHEME\fR Overrides all other color schemes.
|
|
|
|
\fBIRC_COLOR_SCHEME\fR Desktop X/Wayland IRC CLI color scheme.
|
|
|
|
\fBIRC_CONS_COLOR_SCHEME\fR Out of X/Wayland, IRC CLI color scheme.
|
|
|
|
\fBIRC_X_TERM_COLOR_SCHEME\fR In X/Wayland IRC client terminal color scheme.
|
|
|
|
\fBVIRT_TERM_COLOR_SCHEME\fR Color scheme for virtual terminal output (in X/Wayland).
|
|
|
|
.SH BUGS
|
|
Please report bugs using the following resources.
|
|
|
|
You may be asked to run the inxi debugger tool (see \fB\-\-debug 21/22\fR), which will
|
|
upload a data dump of system files for use in debugging inxi. These data dumps are
|
|
very important since they provide us with all the real system data inxi uses to parse
|
|
out its report.
|
|
.TP
|
|
.B Issue Report
|
|
File an issue report:
|
|
.I https://github.com/smxi/inxi/issues
|
|
.TP
|
|
.B Developer Forums
|
|
Post on inxi developer forums:
|
|
.I https://techpatterns.com/forums/forum\-32.html
|
|
.TP
|
|
.B IRC irc.oftc.net#smxi
|
|
You can also visit
|
|
.I irc.oftc.net
|
|
\fRchannel:\fI #smxi\fR to post issues.
|
|
|
|
.SH HOMEPAGE
|
|
.I https://github.com/smxi/inxi
|
|
|
|
.I https://smxi.org/docs/inxi.htm
|
|
|
|
.SH AUTHOR AND CONTRIBUTORS TO CODE
|
|
|
|
.B inxi
|
|
is a fork of \fBlocsmif\fR's very clever \fBinfobash\fR script.
|
|
|
|
Original infobash author and copyright holder:
|
|
Copyright (C) 2005\-2007 Michiel de Boer aka locsmif
|
|
|
|
inxi version: Copyright (C) 2008\-20 Harald Hope
|
|
|
|
This man page was originally created by Gordon Spencer (aka aus9) and is
|
|
maintained by Harald Hope (aka h2 or TechAdmin).
|
|
|
|
Initial CPU logic, konversation version logic, occasional maintenance fixes,
|
|
and the initial xiin.py tool for /sys parsing (obsolete, but still very much
|
|
appreciated for all the valuable debugger data it helped generate): Scott Rogers
|
|
|
|
Further fixes (listed as known):
|
|
|
|
Horst Tritremmel <hjt at sidux.com>
|
|
|
|
Steven Barrett (aka: damentz) \- USB audio patch; swap percent used patch.
|
|
|
|
Jarett.Stevens \- \fBdmidecode \-M\fR patch for older systems with no \fB/sys\fR.
|
|
|
|
.SH SPECIAL THANKS TO THE FOLLOWING
|
|
|
|
The nice people at irc.oftc.net channels #linux\-smokers\-club and #smxi,
|
|
who all really have to be considered to be co\-developers because of their
|
|
non\-stop enthusiasm and willingness to provide real\-time testing and debugging
|
|
of inxi development.
|
|
|
|
Siduction forum members, who have helped get some features working by providing
|
|
a large number of datasets that have revealed possible variations, particularly for the
|
|
RAM \fB\-m\fR option.
|
|
|
|
AntiX users and admins, who have helped greatly with testing and debugging,
|
|
particularly for the 3.0.0 release.
|
|
|
|
ArcherSeven (Max), Brett Bohnenkamper (aka KittyKatt), and Iotaka, who always
|
|
manage to find the weirdest or most extreme hardware and setups that help make
|
|
inxi much more robust.
|
|
|
|
For the vastly underrated skill of output error/glitch catching, Pete Haddow. His
|
|
patience and focus in going through inxi repeatedly to find errors and inconsistencies
|
|
is much appreciated.
|
|
|
|
All the inxi package maintainers, distro support people, forum moderators,
|
|
and in particular, sys admins with their particular issues, which almost always
|
|
help make inxi better, and any others who contribute ideas, suggestions, and patches.
|
|
|
|
Without a wide range of diverse Linux kernel\-based Free Desktop systems to test
|
|
on, we could never have gotten inxi to be as reliable and solid as it's turning
|
|
out to be.
|
|
|
|
And of course, a big thanks to locsmif, who figured out a lot of the core methods,
|
|
logic, and tricks originally used in inxi Gawk/Bash.
|